https://www.trongkamol.com/product-page/bs-250has-%E0%B9%80%E0%B8%84%E0%B8%A3%E0%B8%B7%E0%B9%88%E0%B8%AD%E0%B8%87%E0%B9%80%E0%B8%A5%E0%B8%B7%E0%B9%88%E0%B8%AD%E0%B8%A2%E0%B8%AA%E0%B8%B2%E0%B8%A2-%E0%B9%80%E0%B8%84%E0%B8%A3%E0%B8%B7%E0%B9%88%E0%B8%AD%E0%B8%87%E0%B9%80%E0%B8%A5%E0%B8%B7%E0%B9%88%E0%B8%AD%E0%B8%A2%E0%B8%AA%E0%B8%B2%E0%B8%A2%E0%B8%9E%E0%B8%B2%E0%B8%99%E0%B9%81%E0%B8%99%E0%B8%A7%E0%B8%99%E0%B8%AD%E0%B8%99-%E0%B9%80%E0%B8%84%E0%B8%A3%E0%B8%B7%E0%B9%88%E0%B8%AD%E0%B8%87%E0%B9%80%E0%B8%A5%E0%B8%B7%E0%B9%88%E0%B8%AD%E0%B8%A2%E0%B8%A3%E0%B8%B0%E0%B8%9A%E0%B8%9A%E0%B8%AD%E0%B8%B1%E0%B8%95%E0%B9%82%E0%B8%99%E0%B8%A1%E0%B8%B1%E0%B8%95%E0%B8%B4
top of page
Veo3

Veo3

Retaining the best features of the established Veo line, the new Veo3 now offers a PCAP touch interface, user templates, and more importantly, live TFM.

Key design elements of the Veo3 are user and performance focused.  Based on superior and innovative digital technology and its live concurrent multi-scan / multi-technique capabilities, the Veo3 truly helps you to inspect with confidence.

GENERAL PHASED ARRAY (32:128PR) UT-TOFD (2PR) Live TFM
Multiscan Quantity Up to 8 scans Up to 2 scans (UT & TOFD) Up to 6 scans
Pulsers/Receivers 32:128PR 2PR (4 connectors) Up to 64 elements probe
Gain Range 80dB 100dB 80dB
Sampling Frequency 125 MHz @ 12-Bit 50/100/200 MHz @ 10-Bit 1 125 MHz @ 12-Bit (processing 16-Bit)
System Bandwidth 0.2 to 23 MHz 0.2 to 18 MHz 0.2 to 23 MHz
Max Pulse Rate Frequency 50,000 Hz 20,000 Hz 50,000 Hz
Pulse Voltage 100-50V ActiveEdge© 400-100V ActiveEdge© 1 100-50V ActiveEdge©
Focusing Mode Natural or Constant Depth/Path/ Offset na Focusing in all points TFM & two TFM Intermode methods
S-Scan Resolution Up to 0. 1° na Down to 0.01mm
L-Scan Resolution Down to 1 element or Double Resolution na Down to 0.01mm
Max PA Beams (focal laws) Up to 1024 beams na Up to 500,000 Pixels
Tools – Measurements and Wizard EXTRACTION BOX, 4 gates/A-Scan, TCG, DAC/Split-DAC 4 gates/A-Scan, TCG, DGS/ Split DGS, DAC/Split-DAC 12 TFM algorithms, Up to 4 modes per TFMiTM, EXTRACTION BOX, 4 gates, Velocity, TCG, Amplitude fidelity, up to 20 cursors/view
Onboard Scan Plan Tools Onboard 3D live rendering Power Input 6 hours (hot swappable batteries)
Onboard Reporting Tools PDF auto-report, Export data to CSV file, Save screen capture Power Input AC 110V/240V @ 50 Hz/60 Hz
Onboard PDF Reader Integrated Ability to load and read and PDF documents Unit Dimensions 115 x 220 x 325 mm (4.52 x 8.6)
Online Help Calibration ACTIVE help genius for parameter optimisation procedures, reports Weight 5.1 kg (11 lb) no battery, 460g
Standards ISO18563 (EN16392) & EN12668 Environmental Rating Designed for: IP66

 

bottom of page